Product Description
Description
For solar users who want to connect to shore power when available, the Renogy 3000W Pure Sine Wave Inverter Charger is the perfect component to complete your system. Like most inverters, the Renogy inverter charger converts DC power to AC power for household appliance use. Unlike regular inverters, power inverter chargers can also charge and maintain a battery bank when connected to shore power. Essentially acting as a battery charger and inverter all-in-one, this allows users to travel with ease, using shore power to charge batteries and power devices on rainy days with no sun in sight.
Key Features
- Surge ratings of 6000W
- Maximum bypass current of 40A
- DC and AC inputs Power Saving Mode
- 4 Stage Battery Charger
- 8 Pre-Set Battery Voltages
- Automatic Generator Start Option
General | |
---|---|
Nominal Voltage: 120 VAC | Low Voltage Trip: 90 ± 4% |
Low Voltage Re-engage :100V ± 4% | High Voltage Trip: 140V ± 4% |
High Voltage Re-engage: 135V ± 4% | Max AC Input Voltage: 150 VAC |
Nominal Input Frequency: 50Hz or 60Hz (Auto Detect) | Low Frequency Trip: 57Hz for 60Hz |
High Frequency Trip: 65Hz for 60Hz | Output Waveform: Bypass Mode |
Overload Protection:Circuit Breaker | Short Circuit Protection :Circuit Breaker |
Transfer Switch Rating: 30A | Efficiency on Line Transfer Mode: 95% |
Line Transfer Time: 10ms | Dimensions: 17.5x8.5x7 Inches |
Weight: 53 lbs | Max Bypass Current: 30A |
Bypass Over-load Current: 37.5A | |
Inverter Charger Specification Output | |
Output Wave Form: Pure Sine Wave | Output Continuous Watts: 3000W |
Continuous Power VA: 3000W | Power Factor: 0.9-1.0 |
Nominal Output Voltage RMS: 120VAC | Output Voltage Regulation:± 10% RMS |
Output Frequency: 60Hz ± 0.3Hz | Nominal Efficiency: >88% |
Surge Ratings: 6000W | Short Circuit Protection:Yes, fault after 1 second |
Inverter Charger Specification Input | |
Nominal Input Voltage: 12V | Minimum Start Voltage: 10V |
Low Battery Alarm: 10.5V | Low Battery Trip: 10V |
High Voltage Alarm:16V | Power Saver: <25W |
Inverter Charger Mode Specification | |
Input Voltage Range: 99-130VAC | Output Voltage: 12V |
Charge Current: 80A MAX | Battery Initial Voltage for Startup: 10V |
Over Charge Protection Shutdown: 15.7V |
Warranty Information
Inverters |
1-year material and workmanship warranty |